Your browser is not supported. For the best experience, you should upgrade to a modern browser with improved speed and security.
Click here for information on new branch procedures as a result of COVID-19

Carrier® WeatherMaster® - 6 Ton Packaged Rooftop High Efficiency Cool Only & Electric Heat (208/230-3-60)

Item: 50HCBD07D1M5-6U4M0
MFR: 50HCBD07D1M5-6U4M0

Store Inventory

Sign in to see real-time inventory at the stores closest to you.
What’s the price?
Sign in for pricing.

About This Product

Product Info

Description

50HCBD07D1M5-6U4M0
50
= Electric Heat Packaged Rooftop / Unit Heat Type
HC = High Efficiency / Model Series - WeatherMaster®
B = Medium Electric Heat / Heat Options
D = Two stage cooling models / Refrig. Systems Options
07 = 6 Ton / Cooling Tons
D = RA + SA Smoke Detector / Sensor Options
1 = Standard Static Option - Belt Drive / Indoor Fan Options 6-12.5 Ton Models Only
M = Al/Cu - Al/Cu - Louvered Hail Guard / Coil Options (RTPF) (Outdoor - Indoor - Hail Guard)
5 = 208-230/3/60 / Voltage
- = Factory Design Revision
6 = Electro-mechanical w/ 2-speed fan and W7220 Econo controller controls. Can be used with W7220 EconoMi$er X (w/ Fault Detection & Diagnostic) / Base Unit Controls
U = Low Leak Temperature Economizer w/ Barometric Relief / Intake / Exhaust Options
4 = Hinged Panels and Unpowered Convenience Outlet / Service Options
M = 2-Speed Fan Controller (VFD) with Non-Fused Disconnect and Thru-The-Base Connections / Electrical Options
0 = Standard / Factory Assigned


Features and Benefits:
  • Single-stage cooling capacity control on 04 to 07 models
  • Two-stage cooling capacity control on 08-14 models
  • SEER up to 15.6. EER up to 13.0. IEER’s up to 13.2 with single speed indoor fan motor and up to 14.5 with SAV (Staged Air Volume) 2--speed/VFD indoor fan motor system
  • Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Single point electrical connection
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
  • TXV refrigerant metering system on each circuit
  • Fully insulated cabinet
  • Cooling operating range up to 125°F (52°C), and down to 35°F (2°C), 0°F (-18°C) on 11 size standard
  • Access panels with easy grip handles
  • Innovative , easy starting, no-strip screw feature on unit access panels
  • Two-inch disposable return air filters
  • Tool-less filter access door
  • Belt drive evaporator-fan motor and pulley combinations available on all three phase models
  • Electric Drive X13 (5 speed/torque) motor on 04 to 06 models
  • New terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement
  • Field Convertible airflow (3-12.5 ton). Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome job site complications. 12.5 ton models require a simple supply air duct cover to field convert from factory vertical to horizontal.
  • Provisions for thru-the-bottom power entry capability as standard
  • Full perimeter base rail with built-in rigging adapters and fork truck slots
  • Scroll compressors with internal line-break overload protection
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Low Pressure switch and high-pressure switch protection
  • Liquid line filter drier on each circuit
  • Factory-installed Humidi-MiZerR adaptive dehumidification system on all sizes, includes MotorMaster I controller.
  • Standard Warranty: 5 years electric heater exchanger, 5 years compressor, 1 year parts
  • Optional Staged Air Volume (SAV) system utilizes a Variable Frequency Drive (VFD) to automatically adjust the indoor fan motor speed between cooling stages. Available on 2-stage cooling models 08-14 with electromechanical, ComfortLink or RTU Open controls.
Warning: this product contains a chemical known to the State of California to cause cancer. P65Warnings.ca.gov

Specifications

Weight860 Pounds (lbs)
Width59 Inches (In)
Height49 Inches (In)
Country of OriginVar
Length88 Inches (In)
Air FlowConvertible
Blower Motor HP1 7/10 BHP
Blower Motor RPM489-747
Blower Motor Speeds2 (Two)
Blower Motor TypeBelt Drive
Blower Wheel15" x 15"
BrandCarrier
Circuit Breaker - Max Amps45
Circuit Breaker - Min Amps31
ColorGray
CompressorScroll
Condenser Motor HP1/4 HP
Condenser Motor RPM1100
Condenser Motor Speeds1 (Single)
Condenser Motor TypeDirect Drive
Cooling Capacity72000
Cooling Rated Capacity Btu/h72000
Cycle/Hertz60 Hz
Drain Connection Size3/4"
Drive TypeBelt
EER12.2
Electric Heat Range [kW]4.9-24.3
Energy Star RatedNo
ETL ListedYes
Filter Size(4) 16" x 20" x 2" RA, (1) 20" x 36" x 1" OA
IEER16.2
Locked Rotor Amps136
PhaseThree
Product Family50HC
Prop 65Yes
Rated Load Amps17.5
RefrigerantR-410a
Sound Level (dBA)82
StageTwo
Tonnage6
UL ListedYes
Voltage208-230 VAC
Warranty OfferedYes

Documents

Loading...

Equipment Part List

Loading...